Product Numbers:2015127162224
Price:10
Product introduction:The ignition wire oxygen bomb calorimeter tungsten nichrome wire diameter 0.1, 0.2 and 0.3mm
量
Special ignition wire for oxygen bomb calorimeter
Calorimeter in the
detection of coal heating value, in full of oxygen in the oxygen bomb,
add to the detection of the coal sample, installed ignition device (in
the oxygen bomb), put an ignition wire, and then sealed lit. After
calorimeter will automatically read out calorific value.
Material: high quality nickel wire;
In diameter, 0.1, 0.12, 0.15, 0.18, 0.20, 0.3mm;
Calorific value: 25J/10CM, 42J/10CM, 50J/10CM, etc.
Usage: it is used in
coal laboratory instrument calorimeter, 0.3mm for ignition wire burned
cotton ignition; below 0.2 for ignition wire direct ignition and
ignition wire burned cotton ignition.
Method for correct use of ignition wire:
Good ignition wire, in
the air through the test. Ignition on the cotton thread, the voltage
regulation make ignition wire to dark red in the 4s-5s in fuse ignition,
voltage regulation make ignition wire in the 1s-2s achieve a bright
red;. Voltage, current, and power time should be measured accurately, so
that the heat generated by the electric energy can be calculated. Such
as the use of cotton ignition, in covering fire cover more than two
electrode room for connecting a direct about 0.3mm bromide chromium
wire, wire in the middle of the pre firing spiral laps to fever.
Note: 1 ignition
voltage should be determined in advance, the ignition wire can be used
to determine the heat of the metal wire, as long as the ignition is
successful and to ensure the safety of the test time.
2 in the regulation of
the amount of thermal instrument ignition current, the first ignition
wire plug in the oxygen bomb on the two electrode, and then manually
ignition. In the middle of the air, the red is red, and the current size
is appropriate. Such as the ignition wire burning in the air, the
amount of heat meter current is too large. Such as the ignition wire in
the air is not red, the amount of heat meter current is too small.
Failure analysis and processing method of ignition failure:
If the ignition wire has been broken, and the reasons are not sample burning:
1 the ignition wire is too far from the sample.
2 insufficient oxygen or oxygen bomb.
Such as the ignition
wire is not burned, can be a wire bundle on two ignition electrodes,
running the ignition test function, to see if the fire wire is burned,
such as the ignition wire burning, ignition failure reason for the
ignition electrode and oxygen bomb contact problem or oxygen bomb
itself:
1 ignition electrode rod port or oxygen bomb cover the surface oxide layer, to be polished with sandpaper.
2 on the ignition
electrode is not enough to contact the spring, so that it can not
contact the oxygen bomb cover, replace the spring.
3 oxygen bomb inside the insulation board and the ignition electrode short circuit, it is required to re adjust its position.
The 4 bomb inside the ignition wire fixing nut port of an oxide layer, to be polished with sandpaper.
Such as the ignition wire is not burned, the ignition failure of the reasons:
1 ignition power line or line.
2 ignition circuit damage.
Calorimeter supplies: ignition wire roll and two kinds of packaging box;
|
|
|
|
盒式点火丝
Specifications: diameter of 0.12*100 and 0.10*100; |
|
Ignition wire / calorimeter (Nie Gesi) / fa
300 per box, 0.12 mm in diameter, 80-100 mm in length, 50 in the combustion heat value.
0.1mm-0.2mm of platinum, copper, nickel wire, or other known calorific value.
Genus of silk or cotton, such as cotton, should choose uniform thickness, not wax coated with white cotton thread, ignition wire ignition release heat are as follows:
Wire: 6700J/g: 6000J/g: 2500J/g copper nickel wire thread: 17500J/g.